Physics
Physics, 18.04.2020 02:43, KubraDskn

Deduce a value for the latent heat of evaporation Lv of water. State clearly any simplifying assumptions that you make. Estimate the pressure at which ice and water are in equilibrium at −2◦C given that ice cubes float with 4/5 of their volume submerged in water at the triple point (0.01◦C, 612Pa). [Latent heat of sublimation of ice at the triple point, Ls = 2776 °´ 103 Jkg−1.]

answer
Answers: 3

Other questions on the subject: Physics

image
Physics, 21.06.2019 14:40, shay68596
An implanted pacemaker supplies the heart with 72 pulses per minute, each pulse providing 6.0 v for 0.65 ms. the resistance of the heart muscle between the pacemaker’s electrodes is 550 ω. find (a) the current that flows during a pulse, (b) the energy delivered in one pulse, and (c) the average power supplied by the pacemaker.
Answers: 3
image
Physics, 21.06.2019 22:40, mtassy85
Um vetor representa um deslocamento cujo módulo é 20 m. se v faz um ângulo de 60 graus com a horizontal, qual é o valor das componentes horizontal e vertical deste vetor?
Answers: 2
image
Physics, 22.06.2019 03:00, ambercuevas2707
An internally reversible refrigerator has a modified coefficient of performance accounting for realistic heat transfer processes of where qin is the refrigerator cooling rate, qout is the heat rejection rate, and is the power input. show that copm can be expressed in terms of the reservoir temperatures tc and th, the cold and hot thermal resistances rt, c and rt, h, and qin, as where rtot rt, c rt, h. also, show that the power input may be expressed as 1.39 a household refrigerator operates with cold- and hot-temperature reservoirs of tc 5 c and th 25 c, respectively. when new, the cold and hot side resistances are rc, n 0.05 k/w and rh, n 0.04 k/w, respectively. over time, dust accumulates on the refrigerator’s condenser coil, which is located behind the refrigerator, increasing the hot side resistance to rh, d 0.1 k/w. it is desired to have a refrigerator cooling rate of qin 750 w. using the results of problem 1.38, determine the modified coefficient of performance and the required power input w under (a) clean and (b) dusty coil conditions. internally reversible refrigerator qout qin w high-temperature reservoir low-temperature reservoir th th, i tc, i tc high-temperature side resistance low-temperature side resistance w qin th tc qinrtot tc qinrtot copm tc qinrtot th tc
Answers: 2
image
Physics, 22.06.2019 16:30, stodd9503
The sound level near a noisy air conditioner is 70 db. if two such units operate side by side, the sound level near the, would bea. 70dbb. 73 dbc. 105 dbd 140 db
Answers: 3
Do you know the correct answer?
Deduce a value for the latent heat of evaporation Lv of water. State clearly any simplifying assumpt...

Questions in other subjects:

Konu
Health, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01
Konu
Mathematics, 10.09.2020 07:01