A balanced three-phase 60 Hz source supplies power to a balanced A-connected inductive load. The line voltage is 440 V, the line current is 8.2 A, and the power delivered to the load is 5 kW.

(a) Calculate the load impedance per phase.
(b) Find the complex power generated by the source
(c) What should be done to increase the power factor to unity? Give the value of any component added to the circuit (per phase).

answer
Answers: 2

Other questions on the subject: Physics

image
Physics, 21.06.2019 22:50, Bt758
Two horizontal plates with infinite length and width are separated by a distance h in the z direction. the bottom plate is moving at a velocity u. the incompressible fluid trapped between the plates is moving in the positive x-direction with the bottom plate. align gravity with positive z. assume that the flow is fully-developed and laminar. if the systems operates at steady state and the pressure gradient in x-direction can be ignored, do the following: 1. sketch your system 2. identify the coordinate system to be used. 3. show your coordinates and origin point on the sketch. list all your assumptions. 5. apply the continuity equation to your system. nts of navier stokes equations of choice to your system 7. solve the resulting differential equation to obtain the velocity profile within the system make sure to list your boundary conditions. check units of velocity 8. describe the velocity profile you obtain using engineering terminology. sketch that on the same sketch you provided in (1). 9. obtain the equation that describes the volumetric flow rate in the system. check the units.
Answers: 2
image
Physics, 22.06.2019 10:00, jeffffffff
**urgent** roberto plans to use two transformers to reduce a voltage of 120 v to 4 v. he uses a transformer that has 300 coils in the primary winding and 50 coils in the secondary winding. he has four other transformers, as listed in the table. which transformer should roberto use to have an ending voltage of 4 v? a- w b-xc- yd- z
Answers: 1
image
Physics, 22.06.2019 21:30, missy9225
A1500 w electric heater is plugged into the outlet of a 120 v circuit that has a 20 a circuit breaker. you plug an electric hair dryer into the same outlet. the hair dryer has power settings of 600 w, 900 w , 1200 w, and 1500 w. you start with the hair dryer on the 600 w setting and increase the power setting until the circuit breaker trips. under what setting does the circuit breaker trip.
Answers: 2
image
Physics, 22.06.2019 21:30, tinalmath
Contrast the force of gravity between these pairs of objects: 1-kg mass and a 2-kg mass that are 1 m apart; a 1-kg mass and a 2-kg mass that are 2 m apart; and two 2=kg masses that are 1 m apart. i dont understand.
Answers: 3
Do you know the correct answer?
A balanced three-phase 60 Hz source supplies power to a balanced A-connected inductive load. The lin...

Questions in other subjects: