Engineering
Engineering, 14.12.2021 01:00, kitykay2776

An estimate of the uncertainty for the concentration of an unknown sample can be determined based on the uncertainty in the calibration data set and the unknown sample analysis. The uncertainty (Sx) value is unitless when using the internal standard method of calibration. The uncertainty needs to be expressed in terms of the concentration units used for the standards (i. e. ppm). Calculated the uncertainty value in terms of concentration (Sc) for the diluted AND undiluted sample based on the following information. Uncertainty (Sx; unitless) based on the calibration data set and the unknown sample. Sx = 0.0152

Sample preparation: A whiskey sample is prepared for analysis by GC-FID using the internal standard method of calibration. A 20 mL sample is transferred using a volumetric pipet to a 50 mL volumetric flask. A volume of stock solution of the internal standard is added to the sample flask. The flask is diluted to volume.

Concentration of the internal standard in the diluted unknown = 500 ppm.

A. Sc(dilute) = 8 ppm, Sc(undilute) = 20 ppm
B. Sc(dilute) = 7 ppm, Sc(undilute) = 19 ppm
C. Sc(dilute) = 7.75 ppm, Sc(undilute) = 19.31 ppm
D. Sc(dilute) = 8 ppm, Sc(undilute) = 30 ppm

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, qwertylol12345
Different types of steels contain different elements that alter the characteristics of the steel. for each of the following elements, explain what the element does when alloyed with steel.
Answers: 2
image
Engineering, 04.07.2019 18:10, siri5645
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
image
Engineering, 04.07.2019 18:10, aliopqwas
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
image
Engineering, 04.07.2019 18:10, Larkinlover703
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
Do you know the correct answer?
An estimate of the uncertainty for the concentration of an unknown sample can be determined based on...

Questions in other subjects:

Konu
Chemistry, 24.06.2019 15:00
Konu
Biology, 24.06.2019 15:00