Engineering
Engineering, 26.10.2021 14:40, zavalaaria

A retail store owner reports that the R-410A heat pump serv-ing the store is blowing cold air from time to time and not heating as it normally does. It runs constantly. The unit has a TXV. The technician turns the thermostat to the first stage of the heating mode. The air coming out of the air registers is cool; it feels like the return air. The outdoor unit is on the roof, and the indoor unit is in an attic crawl space. The thermostat is set with the first stage calling for heat; the outdoor unit should be on. The technician goes to the roof. The outdoor unit is running, but the gas line is cool. A gauge manifold is installed on the high and low sides of the system. The low side is operating in a vacuum, and the high-side pressure is 202 psig, which corresponds to the inside temperature of 70°F. This indicates that liquid refrigerant is in the condenser (the indoor coil). If the condenser pressure were 105 psig, well below the 202 psig corresponding to 70°F, it would indicate that the unit is low in refrigerant charge. What is the likely problem and the recommended solution?

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, hadellolo8839
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
image
Engineering, 04.07.2019 18:10, bunnles
During a steady flow process, the change of energy with respect to time is zero. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:20, aly95
An engine runs on the ideal diesel cycle. the cycle has a compression ratio of 20 and a cutoff ratio of 2. the highest temperature in the cycle is 1200 k. if the heat into the system is 300 kj/kg of working fluid and using variable specific heats determine the work produced per mass of working fluid
Answers: 3
Do you know the correct answer?
A retail store owner reports that the R-410A heat pump serv-ing the store is blowing cold air from t...