Engineering
Engineering, 07.10.2021 16:00, avi49

A combined cycle power plant has a net power output of 264 MW. Air enters the compressor of the Brayton cycle at 100 kPa and 17oC. The pressure ratio is 20, the turbine inlet temperature is 1620 K and the gases leaving the turbine are used to heat the steam of the Rankine cycle to 600oC and 6 MPa. The combustion gas leaves the heat exchanger (HRSG) at 400 K and the condenser pressure is 10 kPa. The isentropic efficiency of the compressor is 87%, the gas turbine isentropic efficiency is 90%, the steam turbine isentropic efficiency is 92% and the pump efficiency is 65%. The condenser sub-cools the water by 10oC (10oC less than the saturation temperature). Using variable specific heat analysis, determine

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
image
Engineering, 04.07.2019 18:10, selenamr
Ifa component is made of two or more materials with different modulus of elasticity (e), it is called a composite member and we calculate the factor·n". mention the formula for calculating n". also, ifn> 1, explain what will happen to the 1. transformed. gi) ifn 1, what will happen to the material when transformed material when
Answers: 1
image
Engineering, 04.07.2019 19:10, kelseiroll9759
Ahelical coil spring has a mean diameter of 50 mm, a wire diameter of 5.5 mm and is wound with a pitch of 10 mm. the spring steel has an ultimate strength of 1250 mpa. find the force needed to compress the spring solid and the wire stress in this condition. state whether the spring will return to its initial length.
Answers: 1
image
Engineering, 04.07.2019 19:20, littlepotato10
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
Do you know the correct answer?
A combined cycle power plant has a net power output of 264 MW. Air enters the compressor of the Bray...

Questions in other subjects:

Konu
Social Studies, 01.03.2021 18:20
Konu
History, 01.03.2021 18:20
Konu
History, 01.03.2021 18:20
Konu
Mathematics, 01.03.2021 18:20