Engineering
Engineering, 07.06.2021 16:20, ella3714

Time left 0:42:59 Two balanced three phase loads are connected in parallel, the loads are L,=30 kVA at 0.9 pf lag, and L2= 40 kW at 0.795 pf lag.
The loads are fed from a distribution line with an impedance of 0.1+j0.1 /0. The line to neutral voltage at the load end is 288 V
and zero phase shift, the phase current of the second load in A (if it is A-connected) is;
O A. 26.73-j20.39
O B. 33.35-14.30
O C. 100.04-112.89
O D. 80.19-361.18
O E 46.30-135.32
O F.57.76-17.44
O G. None
Two balanced three phase loads are connected in parallel, the loads are L1=30 KVA at 0.9 pf lag, and L2= 40 kW at 0.795 pf lag.
The loads are fed from a distribution line with an impedance of 0.1+j0.1 92/0. The line to neutral voltage at the load end is 288 V
and zero phase shift, the capacitance of A-connected capacitor bank that connected parallel to the loads to improve the power factor
to unity in uF is; (f=60 Hz)
A 154.92
OB. 51.64
OC 464.76
OD. 1394.28
O E. None​

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 19:30, 10040813
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
image
Engineering, 04.07.2019 18:10, katelynn73
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
image
Engineering, 05.07.2019 23:20, neisha2507
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
Do you know the correct answer?
Time left 0:42:59 Two balanced three phase loads are connected in parallel, the loads are L,=30 kVA...

Questions in other subjects:

Konu
Mathematics, 02.10.2020 14:01
Konu
Mathematics, 02.10.2020 14:01
Konu
Mathematics, 02.10.2020 14:01
Konu
Chemistry, 02.10.2020 14:01