Engineering
Engineering, 19.05.2021 18:50, tammydbrooks43

A new development is being proposed over a 10 acres site. The developer wants to divide the site into 40 lots and have a single-family home at each lot. Each home will take about 40 percent of the lot size. 30% of the lot will be landscaped with shrubs, the rest of the lot will be lawns and sidewalks. After finishing developing the site, the first rainfall of the season hits the development. The rainfall lasted for 3 hours with an average of 0.51 in/hr. Geotechnical report prepared as part of the city permit requirement showed that the initial infiltration was 0.32 in/hr, the final was 0.15in/hr, and decay constant was 0.1 Shr-1. Some residents complained that there was water accumulated at their properties cause some damages. Residents threatened to take legal action against the developer. The developer hired your company to investigate what had happen. You are assigned to the project and been asked by your supervisor to perform the following calculations: 1. What is the interception?
2. What is the infiltration?
3. In your opinion and based on your analysis do you believe that the residents allegations are founded?

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, meganwintergirl
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:10, salazjlove
Which of the following refers to refers to how well the control system responds to sudden changes in the system. a)-transient regulation b)- distributed regulation c)-constant regulation d)-steady-state regulation
Answers: 1
image
Engineering, 04.07.2019 19:20, Katmcfee7681
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
Do you know the correct answer?
A new development is being proposed over a 10 acres site. The developer wants to divide the site int...

Questions in other subjects: