Engineering
Engineering, 06.04.2021 03:10, velaserik1

Size a bioretention filter (without a forebay) to receive a 2,025-m^3wQ, and with a drain time of 1 day from the new development. The design hydraulic conductivity of the media is 0.2-m/d and already includes a safety factor. 75% of the WQv is to be stored over the filter before treatment. The maximum design depth of ponding is 300-mm (=0.3-m). Use a soil media thickness of 0.75-m for the filter. a 1000 m²
b. 7235 m²
c. 5425 m²
d. 1520 m²
e. Cannot be determined with the information provided

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, jadeochoa4466
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
image
Engineering, 04.07.2019 18:20, AnonymousLizard52303
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
image
Engineering, 04.07.2019 19:20, natalie2sheffield
Acompressor compresses a gas, a pump compresses a liquid. for a given pressure ratio, why does it take more work to compress a gas in a compressor than a liquid in a pump? a)- for a given pressure ratio the average specific volume for a gas is much higher than the average specific volume for a liquid. b)- there is no difference. the only difference is the amount of heat generated (not work) c)- for a given pressure ratio the average volurge for a gas is much higher than the average volume for a liquid. d)-there is no difference
Answers: 3
Do you know the correct answer?
Size a bioretention filter (without a forebay) to receive a 2,025-m^3wQ, and with a drain time of 1...

Questions in other subjects:

Konu
Physics, 07.09.2020 22:01