Engineering
Engineering, 08.02.2021 19:10, jjgurl60

The undisturbed soil at a given borrow pit is found to have the following properties: w = 15%; γ= 5 19.1 kN/m^3 ; Gs = 2.70. The soil from this borrow is to be used to construct a rolled fill having a finished volume of 38,500 m3 . The soil is excavated by means of a shovel and dumped onto trucks having a capacity of 4.80 m^3 each. When loaded to capacity, these trucks are found to contain, on the average, a net weight of soil and water equal to 72.7 kN. In the construction process, the trucks dump their load on the fill and the material is spread and broken up, after which a sprinkler adds water until the moisture content is equal to 18%. The soil and water are thoroughly mixed by a disc (or similar equipment) and then compacted until the dry unit weight is equal to 17.3 kN/m^3.
a. Assuming that each load is a full capacity load, how many truckloads are required to construct the fill?
b. What should be the volume of the pit that remains in the borrow area, after all the material required for the fill has been removed?
c. How many liters of water will have to be added per truck load, assuming that the moisture lost by evaporation during excavation, haulage, and handling is negligible?
d. If the fill should become saturated at some time subsequent to the construction and does not change volume appreciably, what will be its water content at saturation?

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, winterblanco
The higher the astm grain-size number, the coarser the grain is. a)-true b)-false
Answers: 3
image
Engineering, 04.07.2019 18:10, chadatkin
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
image
Engineering, 04.07.2019 18:20, jessie8022
Apiston-cylinder device contains 0.1 m3 of liquid water and 0.9 m3 of water vapor in equilibrium at 800 kpa. heat is transferred at constant pressure until the temperature of water reaches 350 °c. determine (a) the quality of water at the initial state (b) the work associated with this process, (c) the heat associated with this process.
Answers: 2
Do you know the correct answer?
The undisturbed soil at a given borrow pit is found to have the following properties: w = 15%; γ= 5...

Questions in other subjects:

Konu
Chemistry, 05.08.2019 01:40