Engineering
Engineering, 21.01.2021 23:00, Fireburntbudder

are calibrated to deliver one fixed volume and are than . Select one: a. Transfer pipets; less accurate; measuring pipets b. Transfer pipets; more accurate; measuring pipets c. Measuring pipets; more accurate; transfer pipets d. None of these answers is correct. e. Measuring pipets; more precise; transfer pipets

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lillygrl100
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
image
Engineering, 04.07.2019 18:10, selenamr
Ifa component is made of two or more materials with different modulus of elasticity (e), it is called a composite member and we calculate the factor·n". mention the formula for calculating n". also, ifn> 1, explain what will happen to the 1. transformed. gi) ifn 1, what will happen to the material when transformed material when
Answers: 1
image
Engineering, 04.07.2019 18:10, wyattlb97
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
image
Engineering, 06.07.2019 03:10, kturvey225
Consider a 1.2 meter high and 2 meter wide glass window whose thickness is 6 mm and thermal conductivity is 0.78 w/m °c. the room temperature is maintained at 24 °c, while the outdoor temperature is -5 °c. the convective heat transfer coefficients on the inner and outer surfaces of the window are 10 w/m2 °c and 25 w/m2 °c respectively. (a) draw the thermal resistance network, etermine the steady rate of heat transfer t e glass window (c) determine the temperature of the inner surface of the window
Answers: 3
Do you know the correct answer?
are calibrated to deliver one fixed volume and are than . Select one: a. Transfer pipets; less accu...

Questions in other subjects:

Konu
Mathematics, 28.11.2021 21:20