Engineering
Engineering, 05.11.2020 18:50, jashart95

Temperature fields in fresh and irradiated fuel (section V) Consider two conditions for heat transfer in the pellet and the pellet-clad gap of a BWR fuel pin. • Initial uncracked pellet with no relocation • Cracked and relocated fuel 1. For each combination, find the temperatures at the clad inner surface, the pellet outer surface, and the pellet centerline.
2. Find for each case the volume-weighted average temperature of the pellet. Geometry and material information Clad outside diameter = 12.52 mm Clad thickness = 0.86 mm Fuel-clad diametral gap = 230 pm Initial solid pellet with density = 88% Basis for heat transfer calculations Clad conductivity is constant at 17 W/m "K Gap conductance Without fuel relocation. 4300 W/m2K, With fuel relocation, 31,000 W/ m K ; Fuel conductivity (average) at 95% density Uncracked, 2.7 W/m K , Cracked, 2.4 W/m 'K; Volumetric heat deposition rate: uniform in the fuel and zero in the clad Do not adjust the pellet conductivity for restructuring. Use Biancharia's porosity correction factor (Eq. 8-21). Operating conditions Clad outside temperature = 295°C Linear heat-generation rate = 44 kW/m

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, breannaasmith1122
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
image
Engineering, 04.07.2019 18:20, miguel454545
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
image
Engineering, 04.07.2019 18:20, 3076850
Prove the equivalence between the two statements of the 2nd law of thermodynamics (i. e., a violation of one statement leads to the violatio the other statement)
Answers: 2
image
Engineering, 04.07.2019 19:20, ijohnh14
Apure substance is a)-mixture of various chemical elements or compounds b)-substance that has a fixed chemical composition throughout c)-mixture that is homogeneous (such as air) d)-all the answers