![Engineering](/tpl/images/cats/User.png)
Engineering, 10.09.2020 04:01, nickocasamplonp6mlob
The minimum fresh air requirement of a residential building is specified to be 0.35 air changes per hour (ASHRAE, Standard 62, 1989). That is, 35 percent of the entire air contained in a residence should be replaced by fresh outdoor air every hour. If the ventilation requirement of a 2.7-m-high, 200-m2 residence is to be met entirely by a fan, determine the flow capacity in L/min of the fan
![answer](/tpl/images/cats/otvet.png)
Answers: 3
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, Strick1530
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
![image](/tpl/images/cats/User.png)
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, maciemarklin79981
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, cxttiemsp021
Atank with constant volume contains 2.27 kg of a mixture of water phases (liquid-vapor). in the initial state the temperature and the quality are 127 °c and 0.6, respectively. the mixture is heated until the temperature of 160 oc is reached. illustrate the process in a t-v diagram. then, determine (1) the mass of the vapor in kg at the initial state, (2) the final pressure in kpa.
Answers: 3
Do you know the correct answer?
The minimum fresh air requirement of a residential building is specified to be 0.35 air changes per...
Questions in other subjects:
![Konu](/tpl/images/cats/mat.png)
Mathematics, 11.10.2021 16:20
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 11.10.2021 16:20
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 11.10.2021 16:20
![Konu](/tpl/images/cats/istoriya.png)
History, 11.10.2021 16:30
![Konu](/tpl/images/cats/biologiya.png)
![Konu](/tpl/images/cats/fizika.png)
![Konu](/tpl/images/cats/fizika.png)
Physics, 11.10.2021 16:30
![Konu](/tpl/images/cats/mat.png)
Mathematics, 11.10.2021 16:30