Tensile test was conducted on a structural steel specimen with a stem diameter 0.26 in. At failure the measured diameter was 0.145 in. The gage length of the sample at the beginning of the test was 1.800 in. and at failure was 2.280 in. The load/deformation data is recorded in the given Excel file. Use Excel to create a stress-strain plot of the data. Include a chart title and axis titles with appropriate units. Calculate the stress-strain data in tabular formPlot the stress-strain diagramDetermine the yield strength, ultimate tensile strength, and rupture(breaking) strengthCalculate the modulus of elasticity, % elongation, and % reduction in areaCompare the values for yield strength and modulus of elasticity with theoretical valuesCalculate the true stress and true strain at failureIdentify the material as brittle or ductileGiven Excel Values:.Load Deformation lb (ΔL) in. 0 0.0000 100 0.0006 200 0.0007 300 0.0008 400 0.0009 500 0.0011 600 0.0012 700 0.0014 800 0.0015 900 0.00171000 0.00181100 0.00191200 0.00201300 0.00221400 0.00231500 0.00241600 0.00261700 0.00271800 0.00501900 0.01002000 0.02002100 0.03002200 0.04002300 0.05002350 0.06002450 0.07002550 0.08002650 0.09002750 0.10002850 0.11002950 0.12003050 0.13003150 0.14003250 0.15003350 0.17003450 0.20003100 0.29002700 0.39002280 0.4800

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, settasav9641
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
image
Engineering, 04.07.2019 18:10, DestyHilBan1183
Adouble-strand no. 60 roller chain is used to transmit power between a 13-tooth driving sprocket rotating at 300 rev/min and a 52-tooth driven sprocket. a) what is the allowable horsepower of this drive? b) estimate the center-to-center distance if the chain length is 82 pitches. c) estimate the torque and bending force on the driving shaft by the chain if the actual horsepower transmitted is 30 percent less than the corrected (allowable) power.
Answers: 3
image
Engineering, 04.07.2019 18:10, colin774
The higher the astm grain size number, the finer the gran is. a)-true b)-false