Engineering
Engineering, 01.09.2020 22:01, sadmomsclub

Verify concepts of phase equilibrium and phase transitions using the steam tables. a. Establish by direct calculation this equality between molar Gibbs free energies for steam at 2.5 MPa and 224oC : Gl = Gv
b. Calculate Gv at 2.5 MPa for temperatures between 225 and 400oC and extrapolate this curve below 224 oC.
c. Find Gl at 160, 170, 180, 190, 200, and 210 oC. Plot in the same graph used for part b and extrapolate above 224 oC. Hint: for a liquid, H and S can be taken as independent of P.
d. Plot the molar volume V vs. T at P =2.5 MPa over the T range between 150 and 400 oC, and show that V is discontinuous.
e. Plot Cp vs. T at P =2.5 MPa over the T range between 150 and 400 oC, and show that Cp is discontinuous.
f. Using the data in the steam tables, show that the Gibbs energies per unit mass of steam and liquid water in equilibrium at 300 oC are equal.

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, namira16
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
image
Engineering, 04.07.2019 19:10, jennymares
Abarometer contains mercury with a density of 13600 kg/m3. atmospheric conditions are 95.8 kpa and 20 °c at 20 °c, the vapor pressure of the mercury is 0.000173 kpa. the column of mercury will rise to a height of most nearly. select one: a)- 0.38 m b)- 0.82 m c)- 0.48 m d)- 0.72 m
Answers: 1
Do you know the correct answer?
Verify concepts of phase equilibrium and phase transitions using the steam tables. a. Establish by...

Questions in other subjects:

Konu
Physics, 26.09.2021 16:00
Konu
Spanish, 26.09.2021 16:00
Konu
English, 26.09.2021 16:00