Engineering
Engineering, 06.06.2020 16:57, kaylag8242p2qj2e

A pH sensor is being used to measure real-time changes in pH of a microbial fuel-cell. An A/D converter with 14 bit resolution and a clock of 3.6 MHz is being used to sample and digitize the voltage readings that lie in a range of 0-10V.1. What is the resolution of the voltage signal? 2. What is the maximum error in Volts? 3. How many bits are needed to achieve a maximum error that is less than 0.2 mV? 4. What is the percent maximum error for V in the range (5 - 10](v)? 5. Find the maximum conversion time if the A/D was a successive approximation register (SAR).6. Suppose that the measurement is corrupted by 3-bit white noise, uniformly distributed. What is the variance of the noise in V and what would be the variance if we perform averaging of N values, where N = 2, 5, 107.

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
image
Engineering, 04.07.2019 18:20, cdyshaylia55
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
image
Engineering, 04.07.2019 19:10, pjgolden04
How to increase the thermal officiency of an ideal simple rankino cycle? among these methods, which one is the best and why?
Answers: 2
image
Engineering, 04.07.2019 19:10, batmanmarie2004
Afoot bridge is made as a simple deck, 4 m long, with a cross section 2 m (wide) and 20 cm thick, and made of wood. the deck is supported at the two ends. the maximum load allowable on the bridge is 10 tons, provided it is uniformly distributed on the deck. to sense this load, a strain gauge is placed at the center of the bridge and its resistance is monitored. if the sensor has a nominal resistance of 350 s2 and a gauge factor of 3.6, what is the reading of the strain gauge at maximum load? the modulus of elasticity for the wood used in the construction is 10 gpa.
Answers: 2
Do you know the correct answer?
A pH sensor is being used to measure real-time changes in pH of a microbial fuel-cell. An A/D conver...

Questions in other subjects:

Konu
Mathematics, 11.03.2021 19:10
Konu
Mathematics, 11.03.2021 19:10
Konu
Mathematics, 11.03.2021 19:10
Konu
Mathematics, 11.03.2021 19:10