Engineering
Engineering, 19.05.2020 18:09, 20alondra04

Installation of a ventless dishwasher is proposed for a commercial kitchen. Typically, commercial dishwashers vent to the exterior so that condensation of water on the interior of the kitchen does not occur. Evaluate the proposed installation and determine whether it will result in condensation. Air flows from the exterior (i. e. ambient conditions) at a rate of 0.5 m3 /s. The exterior conditions may be assumed to be at 10 °C and 80% relative humidity. The manufacturer of the dishwasher reports sensible and latent heat for the dishwasher of 4.386 and 0.731 kW respectively (15,000 and 2500 BTU/hr). You may assume the air flow into the kitchen is large relative to the size of the kitchen so that uniform mixing is occurring1 .

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, brooklyn674
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
image
Engineering, 04.07.2019 18:10, bckyanne3
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
image
Engineering, 04.07.2019 18:10, wirchakethan23
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i. d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
Do you know the correct answer?
Installation of a ventless dishwasher is proposed for a commercial kitchen. Typically, commercial di...

Questions in other subjects: