Engineering
Engineering, 05.05.2020 22:57, ezzyandrade7

The products of combustion from a burner are routed to an industrial application through a thin-walled metallic duct of diameter Di=1 m and length L=100 m. The gas enters the duct at atmospheric pressure and a mean temperature and velocity of Tm, i=1600 K and Um, i=10 m/s, respectively. It must exit the duct at a temperature that is no less than Tm, o=1400 K. What is the minimum thickness of an alumina-silica insulation (Kins=0.125 W/m*K) needed to meet the outlet requirement under worst case conditions for which the duct is exposed to ambient air at T[infinity]=250 K and a cross-flow velocity of V=15 m/s? The properties of the gas may be approximated as those of air, and as a first estimate, the effect of the insulation thickness on the convection coefficient and the thermal resistance associated with the cross flow may be neglected.

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, ijohnh14
Shafts are machine elements that are used to a) carry axial loads b) direct shear loads c) transmit power d) rotate at constant speed e) none of the above circular and square shafts subjected to the same torque under the same circum behave a) the same way b) almost the same way
Answers: 2
image
Engineering, 04.07.2019 19:10, nbunny7208
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces. a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
image
Engineering, 06.07.2019 03:20, leapfroggiez
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
image
Engineering, 06.07.2019 04:30, hallynwright9722
At steady state, air enters an insulated duct of varying cross-sectional area (similar to a nozzle or diffuser) at 200 kpa, 52°c with a mass flow rate of 0.5 kg/s. at the duct exit, the pressure of the air is 100 kpa, the velocity is 255 m/s, and the cross-sectional area is 2 x 10-3 m^2. assuming an ideal gas model, determine: a)-find the specific volume of the air at the exit, in m3/kg. b)- the temperature of the air at the exit, in k. c)-the velocity of the air at the inlet, in m/s. d)-the inlet cross-sectional area, in m^2.
Answers: 1
Do you know the correct answer?
The products of combustion from a burner are routed to an industrial application through a thin-wall...

Questions in other subjects:

Konu
English, 27.09.2019 01:10
Konu
Mathematics, 27.09.2019 01:10