Engineering, 06.05.2020 03:58, andrewmena05

If the DC base-emitter junction voltage, Vbe, for an NPN BJT in the forward-active region is equal to 658 mV then what is the collector current flowing in this BJT, Ic, in milliamps? Assume that the saturation current for this BJT, Is, is equal to 40 fA. (Note that 1 fA = 1 femtoamp = 1 x 10^-15 A.) Neglect the effects of base-width modulation. Also assume that the thermal voltage is equal to Vt = kt/q = 26mV. Since Ic is very sensitive to small changes in Vbe, be sure to use Vbe to the nearest millivolt when calculating your answer!

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
image
Engineering, 04.07.2019 18:10, jojoangelique13
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
image
Engineering, 06.07.2019 03:30, sipstick971
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2
image
Engineering, 06.07.2019 04:10, jessicajustice6215
Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c at a rate of 0.25kg/s and is heated to 45c by hot water (cp=4190j/kg k) that enters at 100c at the rate of 3kg/s. if the overall heat transfer coefficient is 950w /m2 k , determıne the rate of heat transfer and the heat transfer surface area of the heat exchanger using e - ntu method
Answers: 1