Engineering
Engineering, 06.05.2020 08:34, seanholmes91405

An infinitely long rod (k= 200 Wm-'K-?) has a diameter of 40 mm. It is split in two halves, with one half of it exposed to ambient air at a temperature (T.,1) of 20 °C and a convective heat transfer coefficient (hi) of 5 Wm²K-1, and the other half of it exposed to water at a temperature (T.,2) of 15 °C and a convective heat transfer coefficient (h2) of 10 Wm-K-1 Joule heaters apply a heat rate (gb) to the rods at the air/water interface which then dissipates in both directions along the length of the rod. Determine the heat rate (9b) if temperature of the rods at their base (Tb) is 40°C. Assume that the surface emissivity of the rod is negligible. d= 40 mm k= 200 Wm-1K1 Air Toy = 20°C hy = 5 Wm-2K-1 91.1 Heater, 9. = ? 914.2 To = 40 °C Water T.2= 15°C ha= 10 Wm-2K-1

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
image
Engineering, 04.07.2019 19:20, carterdaw
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
image
Engineering, 04.07.2019 19:20, littlepotato10
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
Do you know the correct answer?
An infinitely long rod (k= 200 Wm-'K-?) has a diameter of 40 mm. It is split in two halves, with one...