Question 5 (20 pts) The rated current of a three-phase transmission line is 300 A. The currents flowing by the line are measured with three current transformers each with ratio 250 : 5. What is the current you would measure at the secondary of each current transformer if rated current is flowing through each line. (of course the secondaries of the transformer must be part of closed circuits.) Consider the measured currents are exciting three over-current relays. Should the contacts of the relay close if rated current is circulating in the lines? If your answer is between no and yes, the current that the relay observes when rated current flows by the line must be the minimum pick-up current Ip. Hence, the tap position you should select, e. g., in the tap block of Fig. 1, must be equal o slightly greater than Ip for an over-current relay. Slightly greater when Ip is not an integer that matches the tap selection.

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 19:10, gabrielaperezcz
Air inially occupying a volume of 1 m2 at 100 kpa, 27 c undergoes three internally reversible processes in series. process 1-2 compression to 500 kpa during which pv constant process 2-3 adiabatic expanslon to 100 kpa process 3-1: constant-pressure expansion to 100 kpa (a) calculate the change of entropy for each of the three processes. (b) calculate the heat and work involved in each process. (c) is this cycle a power cycle or refrigeration cycle?
Answers: 3
image
Engineering, 04.07.2019 19:10, kimmy6973
What is creep? what is stress relaxation?
Answers: 1
image
Engineering, 06.07.2019 04:10, ltorline123
Areheat rankine cycle operates with water as the working fluid. steam enters the first turbine at 8 mpa and 450°c and exits at 0.8 mpa. it is then reheated to 400°c before entering the second turbine, where it exits at 10 kpa. if the amount of work into the pump is 8.04 kj/kg and the net work per cycle produced is 1410.25 kj/kg, determine the thermal efficiency of the cycle.
Answers: 3
image
Engineering, 06.07.2019 04:10, makenziemartinez
Aheat pump using refrigerant-134a heats a house by using underground water at 8°c as the heat source. the house is losing heat at a rate of 60,000 kj/h. the refrigerant enters the compressor at 280 kpa and 0°c, and it leaves at 1 mpa and 60°c. the refrigerant exits the condenser at 30°c. determine: (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump
Answers: 2
Do you know the correct answer?
Question 5 (20 pts) The rated current of a three-phase transmission line is 300 A. The currents flow...

Questions in other subjects:

Konu
Social Studies, 14.04.2021 20:20
Konu
Mathematics, 14.04.2021 20:20
Konu
English, 14.04.2021 20:20