Engineering
Engineering, 22.04.2020 02:42, zaylencollins55

EP Electric has identified two new methods to treat its cooling water. Alternative D(for inflow) would treat the raw water with a conventional reverse osmosis system so that the cycles of concentration could be increased from 5 to 20, This will result in water cost savings of $360,000 per year and chemical cost savings of $56,000 per year. The initial cost of the equipment will be $2.3 million with an operating cost of $125,000 per year Alternative B (for blowdown) will treat the cooling tower blowdown water using a highpressure seawater reverse osmosis system to recover most of the water that is sent to an evaporation pond. This option will result in water sav- ings of $270,000 per year. The cost of the system will be $1.2 million with an operating cost of $105,000 per year. Assuming one of the two methods must be installed, determine which is preferred on the basis of the incremental ROR value using MARRof 5%per year, which is a typically low return expected of government projects. Use a 10-year study period with no salvage value for either system. (Note: See Problem 8.41 for more on this situation.)

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lowkeyqueenk
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
image
Engineering, 04.07.2019 18:10, colin774
The higher the astm grain size number, the finer the gran is. a)-true b)-false
Answers: 2
image
Engineering, 04.07.2019 19:20, ijohnh14
Apure substance is a)-mixture of various chemical elements or compounds b)-substance that has a fixed chemical composition throughout c)-mixture that is homogeneous (such as air) d)-all the answers
Answers: 3
image
Engineering, 06.07.2019 03:10, DeathFightervx
Air is flows through an adiabatic nozzle with an inlet pressure of 400 psia at a temperature of 300°f and a velocity of 20 ft/s. the outlet pressure is 40 psia and the velocity is 800 ftl/s. determine the outlet temperature of the air using: a) property tables b) specific heat (using the specific heat value for air at 300°f)
Answers: 3