Engineering
Engineering, 16.04.2020 16:44, larrbear64

An air-conditioning system requires airflow at the main supply duct at a rate of 130 m3/min. The average velocity of air in the circular duct is not to exceed 8 m/s to avoid excessive vibration and pressure drops. Assuming the fan converts 80 percent of the electrical energy it consumes into kinetic energy of air, determine the size of the electric motor needed to drive the fan and the diameter of the main duct. Take the density of air to be 1.20 kg/m3.

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, mm016281
What difference(s) did you notice using a pneumatic circuit over hydraulic circuit. explain why the pneumatic piston stumbles when it hits an obstacle.
Answers: 2
image
Engineering, 04.07.2019 19:10, jimena15
10 kg of co2 is initially contained at 400 kpa and 300 k. the gas constant for carbon dioxide is 189 j/lkg k) and has a specific heat ratio, k, of 1.289. isentropic expansion then occurs until the pressure is 200 kpa. a) determine the initial volume of co2 in m. b) determine the final temperature in k. c) determine the work done by the system during the expansion kl.
Answers: 2
image
Engineering, 04.07.2019 19:10, nayi2002
The short distance from the objective lens to the object causes problems at high magnification. which of the following is the most serious? a. cleaning the object surface b. positioning the object c. reflection from the object surface. d. illumination of the object
Answers: 1
image
Engineering, 04.07.2019 19:20, mercedesamatap21hx0
To design a steam turbine to produce 12,000 hp power. a engineer comsiders using a steady state stean low st 1160fr and engineer considers using a steady state steam flow at 1160°r and 450 psia to drive this steam turbine. the exhaust of the steam is cooled by the lake (vacuum). heat losing to the surroundings is measured at a rate of 555.55 btu/s. (a) sketch the system with the given conditions. (b) neglecting kinetic and potential energy changes from inlet to exit, determine the volumetric flow rate of the steam at the inlet, (ft'/hr). must clearly show unit conversions at crtical terms.
Answers: 1
Do you know the correct answer?
An air-conditioning system requires airflow at the main supply duct at a rate of 130 m3/min. The ave...

Questions in other subjects:

Konu
Mathematics, 10.09.2020 21:01
Konu
Mathematics, 10.09.2020 21:01
Konu
Chemistry, 10.09.2020 21:01
Konu
Chemistry, 10.09.2020 21:01
Konu
Mathematics, 10.09.2020 21:01
Konu
Mathematics, 10.09.2020 21:01
Konu
Mathematics, 10.09.2020 21:01
Konu
Mathematics, 10.09.2020 21:01
Konu
Mathematics, 10.09.2020 21:01
Konu
History, 10.09.2020 21:01