Engineering
Engineering, 15.04.2020 23:43, gshreya2005

A dc shunt generator rated at 85 kW produces a voltage of 280 V. The brush voltage drop is 2.5 V, and the armature and field resistances are 0.09 Ω and 115 Ω, respectively. The generator delivers rated current at rated speed and rated voltage. (a) Calculate the field, armature, and load currents versus load. Test the equations with the rated load. (b) Determine the terminal voltage at no-load and at rated load conditions. (c) Calculate the voltage regulation of the generator. Use the no-load voltage as the base value. (d) Plot the terminal voltage as a function of the load. Determine the load that corresponds to a 5% voltage drop using the no-load voltage as the base

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, brooklyn674
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
image
Engineering, 04.07.2019 16:10, Arealbot
The force on a cutting tool are 2600n vertically downward and 2100 horizontal. determine the resultant force acting on the tool and the angle at which it acts.
Answers: 1
image
Engineering, 04.07.2019 18:20, dlr1628
Acertain flow of air (at stp) has a velocity distribution given by v i (in ft/s). if this flow is going through a 4 ft square area in the yz-plane (centered at the origin), what is the mass flow rate (in lbm/s)?
Answers: 2
image
Engineering, 04.07.2019 18:20, miguel454545
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
Do you know the correct answer?
A dc shunt generator rated at 85 kW produces a voltage of 280 V. The brush voltage drop is 2.5 V, an...

Questions in other subjects:

Konu
Mathematics, 15.05.2021 21:40
Konu
History, 15.05.2021 21:40
Konu
Mathematics, 15.05.2021 21:40