Consider a rack system with a storage rack of dimensions (inches) of 56m (length) by 58n (height), where m is the number of horizontal addresses and n is the number of ver>cal addresses. Assume m = 80, n = 12, and that the S/R requires 0.35 min to perform a P/D opera>on, travels horizontally at an average speed of 350 fpm, and travels ver>cally at an average speed of 60 fpm.

Suppose that 40% of storage and retrieval opera>ons are performed as single command and the remaining are performed as dual command. Assume that there are 120 storages per hr and 120 retrievals per hr and that there are 8 S/R machines that are loaded uniformly.

(i) What is the percent utulization of the S/R machines?

(ii) What is the average cycle time per operation (storage/retrieval)?

(iii) What is the maximum throughput (operations per hour) of this AS/R system?

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 23:20, abbz13
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
image
Engineering, 04.07.2019 18:10, ashleybaber4966
If a particle moves along a path such that r : (3 sin t) m and ? : 2t rad, where t is in seconds. what is the particle's acceleration in m/s in 4 seconds? a)- 16.43 b)- 16.29 c)- 15.21 d)- 13.79
Answers: 1
image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
Do you know the correct answer?
Consider a rack system with a storage rack of dimensions (inches) of 56m (length) by 58n (height), w...

Questions in other subjects: