Engineering, 07.04.2020 02:55, pchisholm100

As a first-year process engineer in industry, you have been tasked with modeling a CSTR carrying out an exothermic reaction. You have been assigned to an elementary reversible liquid-phase reaction, A B , that takes place in a CSTR with a heat exchanger. The feed to the reactor is pure A. Your company desires to sell B, but also wants to be careful about safety and excessive heat generation in the reactor. Additional data: UA = 3600 cal/min*K) E/R = 20,000 K V=20 dm3 Q.= 1 dm3/min FAo = 10 mol/min k=1 min. at 400 K Keq = 100 at 400 K Ambient temperature: T= 37C Feed temperature: T. = 37C Cpa= Cpb = 40 cal/(mol*K) AHRx = -80,000 cal/mol A) A: Derive expression(s) to calculate the "Heat Generated Term", G(T), and do a sample calculation for 400 K. B: What are the steady state temperatures (Hint: graphing this will help)? C: Which steady states are locally stable? Are any unstable, and if so, which one(s)? D: What is the conversion corresponding to the upper steady state? E: Make a plot of reactor temperature as a function of the ambient temperature Ta. We are looking for something that looks like the plot from L15-30. Use excel or your graphical software of choice. F: If the heat exchanger in the reactor suddenly fails, what happens to the UA term, and what would the conversion and reactor temperature be when the new upper steady state is reached (Hint: graphing this will help)? G: What value of UA will give the maximum conversion? H: Suppose you want to operate at the lower steady state. What parameter values would you suggest to prevent runaway?

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 12:10, Ryantimes2
On a average work day more than work place firs are reorted
Answers: 1
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, wyattlb97
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
image
Engineering, 04.07.2019 18:20, krojas015
Asolid cylinder is concentric with a straight pipe. the cylinder is 0.5 m long and has an outside diameter of 8 cm. the pipe has an inside diameter of 8.5 cm. the annulus between the cylinder ad the pipe contains stationary oil. the oil has a specific gravity of 0.92 and a kinematic viscosity of 5.57 x 10-4 m2/s. most nearly, what is the force needed to move the cylinder along the pipe at a constant velocity of 1 m/s?
Answers: 3