Consider an office room that is being cooled adequately by a 12,000 Btu/h window air conditioner. Now it is decided to convert this room into a computer room by installing several computers, terminals, and printers with a total rated power of 8.4 kW. The facility has several 7500 Btu/h air conditioners in storage that can be installed to meet the additional cooling requirements. Assuming a usage factor of 0.4 (i. e., only 40 percent of the rated power will be consumed at any given time) and additional occupancy of seven people, each generating heat at a rate of 100 W, determine how many of these air conditioners need to be installed in the room.

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, jadeochoa4466
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 19:10, batmanmarie2004
Afoot bridge is made as a simple deck, 4 m long, with a cross section 2 m (wide) and 20 cm thick, and made of wood. the deck is supported at the two ends. the maximum load allowable on the bridge is 10 tons, provided it is uniformly distributed on the deck. to sense this load, a strain gauge is placed at the center of the bridge and its resistance is monitored. if the sensor has a nominal resistance of 350 s2 and a gauge factor of 3.6, what is the reading of the strain gauge at maximum load? the modulus of elasticity for the wood used in the construction is 10 gpa.
Answers: 2
image
Engineering, 06.07.2019 03:20, mardell2587
Acountershaft is supported by two tapered roller bearings using indirect mounting. the radial bearing loads are 1120 lb for the left-hand bearing and 2190 lb for the right-hand bearing. the shaft rotates at 400 rpm and is to have an l10 life of 40,000 hours and an application factor of 1.4. assume ka2k 15, and find the required radial rating of each bearing
Answers: 3
image
Engineering, 06.07.2019 04:20, Graciouzgigi1394
Steam in a heating system flows through tubes whose outer radius is 2.5 cm and whose walls are maintained at a temperature of 180 °c . circular aluminum alloy 2024-t6 fins ( k= 186 wm. k) of outer radius 3 cm and constant thickness 1 mm are attached to the tube. the space between the fins is 3 mm and thus there are 250 fins per meter of tube length. heat is transferred to the surrounding air at too-25 °c, with a heat transfer coefficient of 40 w/m2. k. manufacturer a claims that this system is rated at 3.5 kw per meter of tube length. if the fins are an integral part of the steam tube, find the heat transfer rate in kw for a 1-m length of tube. is manufacturer a's claim valid? compare the heat transfer rate from 1 meter of tube length if there are no fins.
Answers: 3
Do you know the correct answer?
Consider an office room that is being cooled adequately by a 12,000 Btu/h window air conditioner. No...

Questions in other subjects:

Konu
History, 20.08.2019 00:30
Konu
World Languages, 20.08.2019 00:30