Engineering
Engineering, 25.03.2020 20:55, imagodatfortnite

Given that the debouncing circuit is somewhat expensive in terms of hardware (2 NAND gates, 2 resistors, and a double-pole, single throw switch), describe applications where you would require switch-debouncing circuits as well as applications where you would not need to include the additional hardware for switch debouncing (in other words, applications where you can tolerate switch bouncing). Note, you cannot use the clock and clear inputs of our lab as example applications; instead you need to think of other examples.

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, BardiFan
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
image
Engineering, 04.07.2019 18:10, 19deleonl
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
image
Engineering, 04.07.2019 18:10, chadatkin
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
Do you know the correct answer?
Given that the debouncing circuit is somewhat expensive in terms of hardware (2 NAND gates, 2 resist...

Questions in other subjects:

Konu
Mathematics, 23.07.2020 23:01
Konu
Mathematics, 23.07.2020 23:01
Konu
Mathematics, 23.07.2020 23:01
Konu
History, 23.07.2020 23:01
Konu
Mathematics, 23.07.2020 23:01
Konu
Mathematics, 23.07.2020 23:01