A 600-MW steam power plant, which is cooled by a nearby river, has a thermal efficiency of 56 percent. Determine the rate of heat transfer to the river water. Will the actual heat transfer rate be higher or lower than this value?
![answer](/tpl/images/cats/otvet.png)
Answers: 1
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, QueenLife4869
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, ultimateapes
When subject to a steady load (within elastic range) over a long period of time, what is the major difference in material behavoir between steel and plastic?
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, rayne40
A)-in the process of engineering design, explain the contribution of material selection. b)- explain the procedure of synthesis as is employed in engineering design. c)- is there any relationship between ergonomics and engineering design? explain. d)- safety consideration in engineering design includes human, product and the enviroment . explain how safety will be incorporated into the design?
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:20, lordcaos066
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
Do you know the correct answer?
A 600-MW steam power plant, which is cooled by a nearby river, has a thermal efficiency of 56 percen...
Questions in other subjects:
![Konu](/tpl/images/cats/mat.png)
Mathematics, 26.03.2021 02:30
![Konu](/tpl/images/cats/mat.png)
Mathematics, 26.03.2021 02:30
![Konu](/tpl/images/cats/fizika.png)
![Konu](/tpl/images/cats/himiya.png)
Chemistry, 26.03.2021 02:30
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/istoriya.png)
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 26.03.2021 02:30
![Konu](/tpl/images/cats/mat.png)