Engineering
Engineering, 14.03.2020 02:43, lekaje2375

A. Choose resistor values R1 and R2so that the DC drain current value is ID1= 100 μA. Assume for this calculation thatλ effects are negligible, i. e., λ≈ 0 V−1. B. For the remaining parts of the problem, consider |λn| = |λp| = 0.01 V−1. It is desired to have the DC output voltage value VO = 5 V. Find the ratio of ID2 to IREF for this case. C. Again considering the DC output voltage value to be VO = 5 V, what is the maximum ac output voltage swing (peak-to-peak) without there occurring significant waveform clipping (i. e., the output voltage range over which Q1 and Q2 remain in saturation)?D. Construct a small-signal equivalent circuit for the amplifier that is appropriate for determining the voltage gain, vo/vi. Clearly identify relevant components and device terminals. E. Solve for the amplifier circuit’s small-signal voltage gain, vo/vi. Begin by writing an expression for the gain, and then determine its value.

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, keigleyhannah30
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
image
Engineering, 04.07.2019 18:10, Tyrant4life
Draw the engineering stress-strain curve for (a) bcc; (b) fcc metals and mark important points.
Answers: 1
image
Engineering, 04.07.2019 18:20, cxttiemsp021
Atank with constant volume contains 2.27 kg of a mixture of water phases (liquid-vapor). in the initial state the temperature and the quality are 127 °c and 0.6, respectively. the mixture is heated until the temperature of 160 oc is reached. illustrate the process in a t-v diagram. then, determine (1) the mass of the vapor in kg at the initial state, (2) the final pressure in kpa.
Answers: 3
image
Engineering, 04.07.2019 19:10, nbunny7208
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces. a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
Do you know the correct answer?
A. Choose resistor values R1 and R2so that the DC drain current value is ID1= 100 μA. Assume for thi...

Questions in other subjects: