A temperature transducer is used to measure the temperature of steam coming out of a steam generator. The following data are available from the manufacturer of the temperature transducer: Range: 0 − 1000 K Sensitivity: ±0.5% of full scale Linearity: ±1.5% of full scale Accuracy: ±1.0% of full scale To determine the repeatability of the transducer, 10 auxiliary tests at the desired average temperature of 800 K were run. The standard deviation of these measurements is 25 K. In a separate test of the data transmission system, 10 tests of the same temperature input resulted in a standard deviation of 20 K. The A/D converter is tested 10 times resulting a standard deviation of 15 K. (a) (10) Calculate the random uncertainty of the temperature measurement at 95% confidence level. (b) (8) Calculate the systematic uncertainty of the temperature measurement. (c) (7) Calculate the total uncertainty of the temperature measurement. If the steam temperature needs to controlled within ±10% from the desired 800 K. Please comment on the adequacy of this device.

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, makaylashrout77
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
image
Engineering, 04.07.2019 18:10, Fahaddie
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
image
Engineering, 04.07.2019 19:10, gabigalvis1091
What is the main objective of using reheat rankine cycle?
Answers: 3
image
Engineering, 04.07.2019 19:10, nayi2002
The short distance from the objective lens to the object causes problems at high magnification. which of the following is the most serious? a. cleaning the object surface b. positioning the object c. reflection from the object surface. d. illumination of the object
Answers: 1
Do you know the correct answer?
A temperature transducer is used to measure the temperature of steam coming out of a steam generator...

Questions in other subjects:

Konu
History, 17.11.2020 16:50
Konu
Arts, 17.11.2020 16:50
Konu
Mathematics, 17.11.2020 16:50
Konu
Chemistry, 17.11.2020 16:50