Engineering
Engineering, 10.03.2020 00:27, hamichrit2412

An air conditioner is designed to bring 10,000 ft3/min of outside air (90°F, 29.8 inches Hg, 88% relative humidity) to 40°F, thereby condensing a portion of the water vapor, and then to reheat the air before releasing it into a room at 65°F. Calculate the rate of condensation (gallons H2O/min) and the volumetric flow rate of the air delivered to the room. (Suggestion: On the flowchart, treat the cooling–condensation and the reheating as separate process steps.)

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, keigleyhannah30
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:10, soreese02
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
Do you know the correct answer?
An air conditioner is designed to bring 10,000 ft3/min of outside air (90°F, 29.8 inches Hg, 88% rel...

Questions in other subjects:

Konu
Mathematics, 14.11.2019 10:31
Konu
Social Studies, 14.11.2019 10:31