Superheated steam at 575 degrees Celsius is routed from a boiler to the turbine of an electric power plant through steel tubes (k = 35 W/m*K) of 300 mm inner diameter and 30 mm wall thickness. To reduce heat loss to the surroundings and to maintain a safe-to-touch outer surface temperature, a layer of calcium silicate insulation (k = 0.10 W/m*K) is applied to the tubes, while degredation of the insulation is reduced by wrapping it in a thin sheet of aluminum having an emissivity of Superheated steam at 575 degrees Celsius is routed . The air and wall temperatures of the power plant are 27 degrees Celsius.(a) Assuming that the inner surface temperature of a steel tube corresponds to that of the steam and an outer convection coefficient of 6 W/m2*K for the aluminum sheet, what is the minimum insulation thickness needed to insure that the temperature of the aluminum does not exceed 50 degrees Celsius? What is the corresponding heat loss per meter of tube length?

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, soreese02
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
image
Engineering, 04.07.2019 18:10, katelynn73
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
image
Engineering, 04.07.2019 18:10, samanthabutryn
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
Do you know the correct answer?
Superheated steam at 575 degrees Celsius is routed from a boiler to the turbine of an electric power...