Engineering
Engineering, 06.03.2020 09:58, kat2177

Find the value of R2 required if vs = 18 V , R1 = 50 kΩ , and the desired no-load output voltage is vo = 6 VPart b)Several different loads are going to be used with the voltage divider from Part A. If the load resistances are 300 kΩ , 200 kΩ , and 100 kΩ , what is the output voltage that is the most different from the design output voltage vo = 6 V ?part c)The circuit designer wants to change the values of R1 and R2 so that the design output voltage vo = 6 V is achieved when the load resistance is RL = 200 kΩ rather than at no-load. The actual output voltage must not drop below 5.4 V when RL = 100 kΩ . What is the smallest resistor value that can be used forR1?

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, bryneosburn
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
image
Engineering, 03.07.2019 14:10, volleyballfun24
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
image
Engineering, 03.07.2019 15:10, brooklyn674
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
Do you know the correct answer?
Find the value of R2 required if vs = 18 V , R1 = 50 kΩ , and the desired no-load output voltage is...

Questions in other subjects:

Konu
Chemistry, 10.11.2020 01:00
Konu
Mathematics, 10.11.2020 01:00