Engineering
Engineering, 03.03.2020 17:31, pmgpmgutube

It takes a resistance heater having 2 kW power to heat a room having 5 m X 5 m X 6 m size to heat from 0 to 33 oC at sea level. Calculate the amount of time needed for this heating to occur in min (Please take Patm=101 kPa, give your answer with three decimals, and do NOT enter units!!!).

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, makaylashrout77
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
image
Engineering, 03.07.2019 19:30, 10040813
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
image
Engineering, 04.07.2019 18:10, ahmedeldyame
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
Do you know the correct answer?
It takes a resistance heater having 2 kW power to heat a room having 5 m X 5 m X 6 m size to heat fr...

Questions in other subjects:

Konu
Mathematics, 15.09.2020 01:01
Konu
Mathematics, 15.09.2020 01:01
Konu
Chemistry, 15.09.2020 01:01
Konu
English, 15.09.2020 01:01
Konu
Social Studies, 15.09.2020 01:01
Konu
Mathematics, 15.09.2020 01:01
Konu
Geography, 15.09.2020 01:01
Konu
Mathematics, 15.09.2020 01:01
Konu
Mathematics, 15.09.2020 01:01
Konu
Mathematics, 15.09.2020 01:01