Engineering, 24.02.2020 17:00, zander434556
A type J thermocouple installed in a process has a reference junction temperature of 100°F and a measurement junction of 315°F. The measured millivolt reading will be equivalent to ? degrees Fahrenheit. (Round the FINAL answer to the nearest whole number.)
![answer](/tpl/images/cats/otvet.png)
Answers: 2
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, alexis9263
Have a greater impact on maintenance productivity than any other support group. (clo5) a)-the top management b)-inventory and purchasing c)-sub-contracting d)-cmms
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, juneham
Estimate the change in specific internal energy au and specific enthalpy h from inlet to outlet for ethylene glycol (a liquid) flowing through each of the following devices: (a) a heat exchanger where the glycol temperature increases from 20 °c to 80 °c; (b) a pump operating at about 25 °c and increasing the glycol pressure from 100 kpa to 8 mpa.
Answers: 2
Do you know the correct answer?
A type J thermocouple installed in a process has a reference junction temperature of 100°F and a mea...
Questions in other subjects:
![Konu](/tpl/images/cats/istoriya.png)
History, 14.11.2019 07:31
![Konu](/tpl/images/cats/mat.png)
Mathematics, 14.11.2019 07:31
![Konu](/tpl/images/cats/himiya.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 14.11.2019 07:31
![Konu](/tpl/images/cats/mkx.png)
Arts, 14.11.2019 07:31
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 14.11.2019 07:31
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/en.png)
English, 14.11.2019 07:31