Engineering
Engineering, 14.02.2020 05:54, elijahjwhite15

A common procedure for measuring the velocity of an air stream involves insertion of an electrically heated wire (called a hot-wire anemometer) into the air flow, with the axis of the wire oriented perpendicular to the flow direction. The electrical energy dissipated in the wire is assumed to be transferred to the air by forced convection. Hence, for a prescribed electrical power, the temperature of the wire depends on the convection coefficient, which, in turn, depends on the velocity of the air. Consider a wire of length L - 20 mm and diameter D = 0.5 mm, for which a calibration of the form. V = 6.25 times 10-5 h2, has been determined. The velocity V and the convection coefficient h have units of m/s and W/m2 K, respectively. In an application involving air at a temperature of Tx = 25 degree C, the surface temperature of the anemometer is maintained at Ts = 75 degree C with a voltage drop of 5 V and an electric current of 0.1 A. What is the velocity of the air?

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, BardiFan
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
image
Engineering, 03.07.2019 15:10, breannaasmith1122
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
image
Engineering, 04.07.2019 03:10, lauriepdx17
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
image
Engineering, 04.07.2019 18:10, qwertylol12345
Different types of steels contain different elements that alter the characteristics of the steel. for each of the following elements, explain what the element does when alloyed with steel.
Answers: 2
Do you know the correct answer?
A common procedure for measuring the velocity of an air stream involves insertion of an electrically...

Questions in other subjects:

Konu
Physics, 05.12.2020 22:00
Konu
Mathematics, 05.12.2020 22:00
Konu
Biology, 05.12.2020 22:00