Engineering
Engineering, 20.12.2019 03:31, AmbitiousAndProud

Air is heated as it flows subsonically through a duct. when the amount of heat transfer reaches 67 kj/kg, the flow is observed to be choked and the velocity and the static pressure are measured to be 680 m/s and 261 kpa. disregarding frictional losses, determine the velocity, static temperature, and static pressure at the duct inlet. take the properties of air to be k = 1.4, cp = 1.005 kj/kg·k, and r = 0.287 kj/kg·k.

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, soreese02
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
image
Engineering, 04.07.2019 18:10, nandalabella06
True or false (explain) (110)[111] is a slip system in bcc metals . the {111} family in fcc contains 8 planes. resolved shear stress (rss) in single crystals is just related to the applied stress. critical resolved shear stress (crss) in single crystal metals is direct proportional to the number of defects in the structure
Answers: 2
image
Engineering, 04.07.2019 19:20, justicehernandez
Acarnot refrigerator operates in a room in which the temperature is 21°c and of power when operating. if the food compartment of the refrigerator is consumes 3 kw to be maintained at 2°c, determine (a) the coefficient of performance of the cycle and (b) the rate of heat removal from the food compartment. refrigerator cycle that has a higher coefficient of performance than that of the discussed (e) is it possible to develop a carn ot refrigerator, operating between the same temperature limits? explain
Answers: 2
image
Engineering, 05.07.2019 23:20, neisha2507
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
Do you know the correct answer?
Air is heated as it flows subsonically through a duct. when the amount of heat transfer reaches 67 k...

Questions in other subjects:

Konu
Mathematics, 05.02.2021 21:40
Konu
Advanced Placement (AP), 05.02.2021 21:40