Engineering
Engineering, 27.11.2019 02:31, jacobballew2019

You wish to capture particles with a 3 µm radius suspended in a fluid that has a linear density gradient with a density of 1.12 g/cm^3 at the bottom and 1.00 g/cm^3 at the top. you layer a thin particle suspension on the top of the 6 cm column of fluid with a viscosity of 1.0 cp and allow particles to settle.
a) how long must you wait for particles with a density of 1.07 g/cm^3 to sediment to within 0.1 cm of their isopycnic level (i. e., within 0.1 cm of the position where the density of the particles and the density of the fluid are equal)?
b) instead of settling due to gravity, you choose to use a centrifuge running at 800 rpm. if the top of the fluid is 5 cm from the center of rotation, how long must you run the centrifuge for the particles to move to within 0.1 cm of their isopycnic level?

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, Strick1530
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
image
Engineering, 04.07.2019 18:10, katelynn73
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
image
Engineering, 04.07.2019 18:20, kendrawalraven
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
Do you know the correct answer?
You wish to capture particles with a 3 µm radius suspended in a fluid that has a linear density grad...

Questions in other subjects:

Konu
Mathematics, 04.09.2020 02:01
Konu
Mathematics, 04.09.2020 02:01
Konu
Mathematics, 04.09.2020 02:01