Engineering
Engineering, 23.11.2019 05:31, gardinerr410

Airflow through a long, 0.15-m-square air conditioning duct maintains the outer duct surface temperature at 10°c. if the horizontal duct is uninsulated and exposed to air at 35°c in the crawlspace beneath a home, what is the heat gain per unit length of the duct? evaluate the properties of air at 300 k. for the sides of the duct, use the more accurate churchill and chu correlations for laminar flow on vertical plates.
what is the rayleigh number for free convection on the outer sides of the duct? 7709251
what is the free convection heat transfer coefficient on the outer sides of the duct, in w/m2·k? 4.87
what is the rayleigh number for free convection on the top of the duct? 965073
what is the free convection heat transfer coefficient on the top of the duct, in w/m2·k? need here
what is the free convection heat transfer coefficient on the bottom of the duct, in w/m2·k? need here
what is the total heat gain to the duct per unit length, in w/m? need here
i cant figure out 4,5 and 6. i swear they are correct but the online homework won't take it.

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, aliceohern
The y form of iron is known as: a) ferrite b) cementite c) perlite d) austenite
Answers: 3
image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
image
Engineering, 04.07.2019 18:10, meganwintergirl
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
image
Engineering, 04.07.2019 18:10, leomessifanboy678
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2