Re-consider the dc motor drive system (k = 147,7 = 0.1) that you examined in problem 2. the goal is to design a feedback controller g (s) to meet the following performance requirements:
p1. the steady-state error caused by a unit constant disturbance torque t, (s) should be zero (steady-state performance specifications).
p2. the unit step response of the closed-loop system to the reference input should have an overshoot of 15% and a 2% setting time of 0.1 sec (transient performance specifications).
a. using the closed-loop transfer function g (s) from the disturbance torque t(s) to the output y(s), obtain the steady-state error caused by a unit constant disturbance torque t, (s) when a pd feedback controller g (s)= k, +ky is used. if you are doing correctly, you will find that the steady-state error obtained is not zero and thus a pd controller cannot satisfy the steady-state performance requirement p1.
b. to satisfy the steady-state performance requirement p1, we can use the following proportional plus integral and derivative (pid) feedback controller: g (5)=k, +k,+k, which can implemented by applying the following physical control input to the plant: u(t)=k_(6)+k„¢t) + k, ſe(t)dt or u(s)=k+k»s+k, e(s) obtain the closed-loop transfer functions gr(s) and g (s) when the above pid feedback controller is used.
c. show that with the above pid controller, as long as the closed-loop system is stable, the steady- state performance requirement p1 will be satisfied.
d. to determine the pid gains kp, k, and k, to satisfy the transient performance requirement p2, we will use the pole placement technique. your denominator of the closed loop transfer function should be third order so you will need to place three poles. determine a desired form for the denominator of the closed loop transfer function such that the dominant poles will be second order with an overshoot of 15% and a 2% setting time of 0.1 sec (as prescribed by requirement p2). place a third pole at -100.
e. determine the pid gains kp, k, and k, which will produce the desired pole locations from part d.

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, cowgyrlup124
Explain the difference laminar and turbulent flow. explain it with the shear stress and the velocity profiles.
Answers: 1
image
Engineering, 04.07.2019 18:10, mm016281
What difference(s) did you notice using a pneumatic circuit over hydraulic circuit. explain why the pneumatic piston stumbles when it hits an obstacle.
Answers: 2
image
Engineering, 04.07.2019 18:10, genyjoannerubiera
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
image
Engineering, 04.07.2019 19:10, Calliedevore
The proportional limit is always greater than the yield strength for a material. a)-trune b)- false
Answers: 3
Do you know the correct answer?
Re-consider the dc motor drive system (k = 147,7 = 0.1) that you examined in problem 2. the goal is...

Questions in other subjects:

Konu
Mathematics, 13.11.2019 15:31
Konu
Mathematics, 13.11.2019 15:31