Awell-insulated 2 m x 5 mx 6 m room initially at 8 °c is heated by the radiator of a steam heating system. the radiator has a volume of 80 l and is filled with superheated vapor at 500 kpa and 400°c. at t = 0 minutes both the inlet and exit valves to radiator are closed. a 40 w fan is used to distribute the air in the room. at t = 45 minutes, the pressure of the steam has dropped to 200 kpa because of heat transfer to the room. assuming constant specific heats for air at room temperature, determine the average temperature of air at t = 45 minutes. assume the air pressure in the room remains constant at 100 kpa.

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, theamandawhite
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
image
Engineering, 04.07.2019 18:10, meganwintergirl
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
image
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
image
Engineering, 04.07.2019 18:20, AnonymousLizard52303
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
Do you know the correct answer?
Awell-insulated 2 m x 5 mx 6 m room initially at 8 °c is heated by the radiator of a steam heating s...

Questions in other subjects:

Konu
Mathematics, 03.03.2021 16:00
Konu
Mathematics, 03.03.2021 16:00