Engineering
Engineering, 06.10.2019 08:00, rose6038

The 600mw power plant has an efficiency of 36% with 15% of the waste heat being released to the atmosphere as stack heat and another 85% taken away in the cooling water. instead of drawing water from the river, heating it, and returning it to the river, this plant uses an evaporative cooling tower wherein heat is released to the atmosphere as cooling water vaporized. at what rate must 15ºc makeup water be provided from the river to offset the water lost in the cooling tower?

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, bryneosburn
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
image
Engineering, 03.07.2019 15:10, breannaasmith1122
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
image
Engineering, 03.07.2019 19:30, 10040813
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
image
Engineering, 04.07.2019 18:10, colin774
The higher the astm grain size number, the finer the gran is. a)-true b)-false
Answers: 2
Do you know the correct answer?
The 600mw power plant has an efficiency of 36% with 15% of the waste heat being released to the atmo...

Questions in other subjects: