By removing energy by heat transfer from
aroom, a window air conditioner maintains the room at 22
degreecelcius on a day when the outside temperature is 32
degreecelcius.
a) determine, in kw per kw of cooling, the minimumtheoretical
power required by the air conditioner.
b) to achieve required rates of heat transfer withpractical
sized units, air conditioners typically recieve energy byheat
transfer at a temperature below that of the room being cooledand
discharge energy by heat transfer at a temperature above thatof the
surroundings. consider the effect of this bydetermining the minimum
theoretical power, in kw per kw of cooling, required when tc = 18
degree celcius and th= 36degree celcius, and compare with the value
found in part(a).

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, kayabwaller4589
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
image
Engineering, 03.07.2019 14:10, volleyballfun24
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
image
Engineering, 04.07.2019 18:10, jadeochoa4466
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.