Engineering
Engineering, 11.09.2019 02:20, Asterisk

Electrically heated draw batch furnaces are commonly used in the heat treatment industry. consider a draw batch furnace front made of a 20-mm thick steel plate with a thermal conductivity of 37 w/m·k. the furnace is situated in a room with surrounding air temperature of 20°c and an average convection heat transfer coefficient of 10 w/m2·k. if the inside surface of the furnace front is subjected to uniform heat flux of 5 kw/m2 and the outer surface has an emissivity of 0.30, determine the inside surface temperature of the furnace front in k. (round your answer up to 2 decimal places.) the stefan–boltzmann constant is 5.67 × 10-8 w/m2 . k4

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, niicoleassssssf
Aflywheel accelerates for 5 seconds at 2 rad/s2 from a speed of 20 rpm. determine the total number of revolutions of the flywheel during the period of its acceleration. a.5.65 b.8.43 c. 723 d.6.86
Answers: 2
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
image
Engineering, 04.07.2019 19:20, anggar20
Air enters a horizontal, constant-diameter heating duct operating at steady state at 290 k, 1 bar, with a volumetric flow rate of 0.25 m°/s, and exits at 325 k, 0.95 bar. the flow area is 0.04 m2. assuming the ideal gas model with k = 1.4 for the air, determine (a) the velocity at the inlet and exit, each in m/s, and (c) the rate of heat transfer, in kw flow rate, in kg/s, (b) the mass kg 0.3
Answers: 2
image
Engineering, 04.07.2019 19:20, lordcaos066
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
Do you know the correct answer?
Electrically heated draw batch furnaces are commonly used in the heat treatment industry. consider a...

Questions in other subjects:

Konu
Computers and Technology, 20.04.2020 22:33
Konu
Mathematics, 20.04.2020 22:33