Engineering
Engineering, 10.09.2019 21:30, petroale000

The small cylinder is made to move along the rotating rod with a motion between r = r0 + b and r0 - b given by r = r0 + b sin(2πt/τ), where t is the time counted from the instant the cylinder passes the position r = r0 and τ is the period of the oscillation (time for one complete oscillation). simultaneously, the rod rotates about the vertical at the constant angular rate . determine the value of r for which the radial (r-direction) acceleration is zero. solve for the case r0 = 330 mm, b = 200 mm, τ = 1.6 s, and = 2.8 rad/s.

answer
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, BardiFan
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
image
Engineering, 03.07.2019 15:10, theamandawhite
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
image
Engineering, 04.07.2019 18:20, ashleyjaslin
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
image
Engineering, 04.07.2019 18:20, safiyabrowne7594
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
Do you know the correct answer?
The small cylinder is made to move along the rotating rod with a motion between r = r0 + b and r0 -...

Questions in other subjects:

Konu
Mathematics, 20.05.2021 20:00
Konu
Mathematics, 20.05.2021 20:00
Konu
Mathematics, 20.05.2021 20:00