Engineering
Engineering, 20.08.2019 23:20, mariehayes099

Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105 kpa (gauge) and a condensing pressure of 920 kpa (gauge). there is a sub-cooling of 3 k with a superheat of the gas entering the compressor of 8 k. the compressor is a four-cylinder reciprocating compressor with a bore of 67 mm and a stroke of 57 mm with an estimated capacity of 35 kw. the compressor is directly coupled to an electric motor running at 1470 rev/min and a power consumption of 19,5 kw. calculate: (a) the clearance volume efficiency if the compressor clearance is 3,6 %; (b) the actual volumetric efficiency; (c) the compression efficiency when the mechanical efficiency is 85% and the motor efficiency 90%.

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
image
Engineering, 04.07.2019 18:10, aaliyah80
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
image
Engineering, 04.07.2019 18:10, krystabrewer3
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
image
Engineering, 04.07.2019 18:20, ashleyjaslin
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
Do you know the correct answer?
Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105 kpa...

Questions in other subjects:

Konu
Mathematics, 20.03.2020 12:01