In a dairy operation, milk at a flow rate of 250 l/h and a cow-body temperature of 38.6c must be chilled to a safe-to-store temperature of 13c or less. ground water at 10c is available at a flow rate of 0.72 m3/h. the density and specific heat of milk are 1030 kg/m3 and 3860 j/kg k, respectively. (a) determine the ua product of a counterflow heat exchanger required for the chilling process. determine the length of the exchanger if the inner pipe has a 50-mm diameter and the overall heat transfer coefficient is u 1000 w/m2 k. (b) determine the outlet temperature of the water. (c) using the value of ua found in part (a), determine the milk outlet temperature if the water flow rate is doubled. what is the outlet temperature if the flow rate is halved?

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, genyjoannerubiera
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
image
Engineering, 04.07.2019 18:10, salazjlove
Which of the following refers to refers to how well the control system responds to sudden changes in the system. a)-transient regulation b)- distributed regulation c)-constant regulation d)-steady-state regulation
Answers: 1
image
Engineering, 04.07.2019 18:10, nandalabella06
True or false (explain) (110)[111] is a slip system in bcc metals . the {111} family in fcc contains 8 planes. resolved shear stress (rss) in single crystals is just related to the applied stress. critical resolved shear stress (crss) in single crystal metals is direct proportional to the number of defects in the structure
Answers: 2
image
Engineering, 04.07.2019 18:10, jojoangelique13
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2