Engineering
Engineering, 13.07.2019 20:20, malayalatham3357

Saturated liquid r-134a enters a heat exchanger at 200 kpa and 1.363 kg/s. the refrigerant cools liquid no. 2 diesel fuel (cp =2.1 kj/kg. k, p=760 kg/m^3) from 89°c to 8°c. the diesel flow rate is 175 liters per minute (1000 l 1 m3). determine: 1)- the rate of heat transfer, in kw 2)-the exit temperature of the refrigerant, in c

answer
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, genyjoannerubiera
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
image
Engineering, 04.07.2019 18:10, katelynn73
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
image
Engineering, 04.07.2019 18:20, maciemarklin79981
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
image
Engineering, 04.07.2019 19:10, jimena15
10 kg of co2 is initially contained at 400 kpa and 300 k. the gas constant for carbon dioxide is 189 j/lkg k) and has a specific heat ratio, k, of 1.289. isentropic expansion then occurs until the pressure is 200 kpa. a) determine the initial volume of co2 in m. b) determine the final temperature in k. c) determine the work done by the system during the expansion kl.
Answers: 2
Do you know the correct answer?
Saturated liquid r-134a enters a heat exchanger at 200 kpa and 1.363 kg/s. the refrigerant cools liq...

Questions in other subjects:

Konu
Health, 07.12.2021 17:00
Konu
Mathematics, 07.12.2021 17:00
Konu
Mathematics, 07.12.2021 17:00
Konu
Mathematics, 07.12.2021 17:00
Konu
Physics, 07.12.2021 17:00