An air conditioner operating at steady state is set maintain an inside temperature of a house at 74°f. if the rate of heat transfer through the walls is 1,420 btu/(hr a°r), b 2.7 (assume constant with changes in outside temperature) and an ideal compressor on the air conditioner operators at 4.2 hp. what is the maximum outside temperature where the house can still maintain its temperature?

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lillygrl100
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
image
Engineering, 04.07.2019 19:20, brae72
Asimple speed reducer is composed of 2 spur gears. the pinion gear has a pitch diameter of 0.75" and 36 teeth while the driven gear has a pitch diameter of 4.0" and 192 teeth. a)-what is the diametral pitch of each gear? b)-if an electric motor rotating ccw at 3000 rpm is coupled to the pinion, what is the rotational speed of the driven gear? c)-if the torque delivered to the pinion is 1 n-m, what is the torque on the driven gear? d)-what is the power transmitted by the gear train?
Answers: 1
image
Engineering, 06.07.2019 03:10, lacourboud20005
An electrical kettle is made out of stainless steel, weighs two pounds (when empty) with a heating element that consumes 2 kw of electricity. assuming that the water and the kettle are at the same uniform temperature at any moment of time, calculate the shortest possible time to bring 2 quarts of water from room temperature to the onset of boiling.
Answers: 1
image
Engineering, 06.07.2019 04:10, blaqsafire9291
Aspherical thermocouple measurement errors a spherical thermocouple made of constantin transfer coefficient between the gas and the thermocouple is h used to measure the temperature of a gas. the heat 400 w/m2 k. calculate the maximum diameter d of the thermocouple if the thermocouple's measurement error should be w 23 within 5% of the initial temperature difference in 5 seconds. for constantin, k 8920 kg/m3, and c 410 j/kg. k.
Answers: 3
Do you know the correct answer?
An air conditioner operating at steady state is set maintain an inside temperature of a house at 74°...

Questions in other subjects:

Konu
Mathematics, 10.11.2020 19:00
Konu
History, 10.11.2020 19:00
Konu
Mathematics, 10.11.2020 19:00
Konu
World Languages, 10.11.2020 19:00
Konu
English, 10.11.2020 19:00
Konu
Mathematics, 10.11.2020 19:00