Engineering
Engineering, 11.07.2019 02:40, ericavasquez824

Explain why it is difficult to break a sheet of paper in tension, but easy to cut it with scissors.

answer
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 19:10, brid7931
Aplate of dimensions 3 m x 3 m is placed 0.37 mm apart from a fixed plate. the plate requires a force of 2n to move at speed of 45 cm/s. evaluate the viscosity of the fluid in between the plates
Answers: 3
image
Engineering, 06.07.2019 03:20, carrietaylor234
Avertical steel rod of length 2.0 m and diameter 25 mm is rigidly fixed at its upper end and has a flange at its lower, free, end. what will be the maximum stress produced in the rod when a load of 20 kn is applied, (a) gradually to the lower end, (b) suddenly to the lower end, (c) by a collar falling from a height of 50 mm on to the flange?
Answers: 3
image
Engineering, 06.07.2019 04:10, keke6361
Consider a power plant with water as the working fluid that operates on an ideal rankine cycle. it has a net power output of 45mw. superheated steam enters the turbine at 7mpa and 500°c (h=3411.4 kj/kg; s=6.8 kj/kg k) and is cooled in the condenser at a pressure of 10 kpa by running cooling water from a lake through the tubes of the condenser at a rate of 2000 kg/s. (a) show the cycle on a t-s diagram (a right schematic is fine - you do not need to calculate the temperatures at each point); (b)-determine the work done by the turbine and the pump in kj/kg; (c)-the mass flow rate of water used by the power plant; (d)-the thermal efficiency of the cycle; (e)-the temperature rise of the cooling water. assume the cooling water is incompressible with cp 4.18 kj/kg°c.
Answers: 3
image
Engineering, 06.07.2019 04:20, Graciouzgigi1394
Steam in a heating system flows through tubes whose outer radius is 2.5 cm and whose walls are maintained at a temperature of 180 °c . circular aluminum alloy 2024-t6 fins ( k= 186 wm. k) of outer radius 3 cm and constant thickness 1 mm are attached to the tube. the space between the fins is 3 mm and thus there are 250 fins per meter of tube length. heat is transferred to the surrounding air at too-25 °c, with a heat transfer coefficient of 40 w/m2. k. manufacturer a claims that this system is rated at 3.5 kw per meter of tube length. if the fins are an integral part of the steam tube, find the heat transfer rate in kw for a 1-m length of tube. is manufacturer a's claim valid? compare the heat transfer rate from 1 meter of tube length if there are no fins.
Answers: 3
Do you know the correct answer?
Explain why it is difficult to break a sheet of paper in tension, but easy to cut it with scissors....

Questions in other subjects:

Konu
Social Studies, 14.06.2021 14:00
Konu
Social Studies, 14.06.2021 14:00
Konu
Biology, 14.06.2021 14:00
Konu
Mathematics, 14.06.2021 14:00
Konu
Health, 14.06.2021 14:00
Konu
SAT, 14.06.2021 14:00